1 | 1 | # xDrip settings |
2 | 2 |
|
3 | | -If not already set up, then download [xDrip](https://jamorham.github.io/#xdrip-plus). |
| 3 | +If not already set up, download and install the latest xDrip release from the [xDrip releases page](https://github.com/NightscoutFoundation/xDrip/releases). |
4 | 4 |
|
5 | 5 | Disable battery optimization and allow background activity for the xDrip app. |
6 | 6 |
|
7 | | -You can safely download the [latest APK (stable)](https://xdrip-plus-updates.appspot.com/stable/xdrip-plus-latest.apk) unless you need recent features or are using sensors that are being actively integrated (like G7), in which case you should use the latest [Nightly Snapshot](https://github.com/NightscoutFoundation/xDrip/releases). |
8 | | - |
9 | 7 | ## Basic settings for all CGM & FGM systems |
10 | 8 |
|
11 | 9 | ### Disable Nightscout upload |
@@ -70,115 +68,56 @@ Remember to disable Import Sounds to avoid xDrip making a ringtone every time AA |
70 | 68 | - If you want to be able to use AAPS to calibrate then in xDrip go to Settings → Interapp Compatibility → Accept Calibrations and select ON. |
71 | 69 | - You may also want to review the options in Settings → Less Common Settings → Advanced Calibration Settings. |
72 | 70 |
|
73 | | -## Dexcom G6 |
74 | | - |
75 | | -* The Dexcom G6 transmitter can simultaneously be connected to the Dexcom receiver (or alternatively the t:slim pump) and one app on your phone. |
76 | | -* When using xDrip as receiver uninstall Dexcom app first. **You cannot connect xDrip and Dexcom app with the transmitter at the same time!** |
77 | | -* If you need Clarity and want to profit from xDrip features, use the [Build Your Own Dexcom App](#DexcomG6-if-using-g6-with-build-your-own-dexcom-app) with local broadcast to xDrip, or use xDrip as a Companion app receiving notifications from the official Dexcom app. |
78 | | - |
79 | | -### xDrip version depending on G6 transmitter serial no. |
80 | | - |
81 | | -* All G6 transmitters manufactured after fall/end 2018 are called "Firefly". They do not allow sensor restart without [removing the transmitter](https://navid200.github.io/xDrip/docs/Remove-transmitter.html), they do not send raw data. It is recommended to use the latest [Nightly Snapshot](https://github.com/NightscoutFoundation/xDrip/releases). |
82 | | -* Old rebatteried transmitters and modified transmitters allow sensor life extension and restarts, they also send raw data. You can use the [latest APK (stable)](https://xdrip-plus-updates.appspot.com/stable/xdrip-plus-latest.apk). |
83 | | - |
84 | | - |
85 | | -### Dexcom specific settings |
86 | | - |
87 | | -* Follow [these instructions](https://navid200.github.io/xDrip/docs/G6-Recommended-Settings.html) to setup xDrip. |
88 | | - |
89 | | - |
90 | | -### Preemptive restarts not recommended |
| 71 | +## Dexcom sensors |
91 | 72 |
|
92 | | -**Only rebatteried or modified Dexcom transmitters. [Preemptive restarts](https://navid200.github.io/xDrip/docs/Preemptive-Restart.html) do not work with standard transmitters and will stop the sensor completely: you need to [remove the transmitter](https://navid200.github.io/xDrip/docs/Remove-transmitter.html) to restart the sensor.** |
| 73 | +Everything related to the Dexcom sensor and transmitter themselves (starting, stopping, replacing, calibrating, troubleshooting) is documented and kept up to date in the [xDrip Dexcom documentation](https://navid200.github.io/xDrip/docs/Dexcom_page.html). Follow those instructions for the sensor; the settings connecting xDrip to **AAPS** (described above on this page) are the only AAPS-specific part. |
93 | 74 |
|
94 | | -The automatic extension of Dexcom sensors (`preemptive restarts`) is not recommended as this might lead to “jumps” in BG values on day 9 after restart. |
| 75 | +### Dexcom G6 and ONE |
95 | 76 |
|
96 | | - |
| 77 | +* Set up xDrip following the [recommended settings](https://navid200.github.io/xDrip/docs/G6-Recommended-Settings.html). |
| 78 | +* The Dexcom G6 and ONE transmitters can simultaneously be connected to the Dexcom receiver (or alternatively the t:slim pump) and one app on your phone. |
| 79 | +* When using xDrip as receiver uninstall the Dexcom app first. **You cannot connect xDrip and the Dexcom app with the transmitter at the same time!** |
| 80 | +* If you need Clarity and want to profit from xDrip features, use the [Build Your Own Dexcom App](#DexcomG6-if-using-g6-with-build-your-own-dexcom-app) with local broadcast to xDrip, or use xDrip as a Companion app receiving notifications from the official Dexcom app (with possible delays in BG readings). |
97 | 81 |
|
98 | | -To use it safely, there are a few points to be aware of: |
| 82 | +#### Sensor restarts |
99 | 83 |
|
100 | | -* If you are using the native data with the calibration code in xDrip or Spike, the safest thing to do is not allow preemptive restarts of the sensor. |
101 | | -* If you must use preemptive restarts, then make sure you insert at a time of day where you can observe the change and calibrate if necessary. |
102 | | -* If you are restarting sensors, either do it without the factory calibration for safest results on days 11 and 12, or ensure you are ready to calibrate and keep an eye on variation. |
103 | | -* Pre-soaking of the G6 with factory calibration is likely to give variation in results. If you do pre-soak, then to get best results, you will probably need to calibrate the sensor. |
104 | | -* If you aren’t being observant about the changes that may be taking place, it may be better to revert to non-factory-calibrated mode and use the system like a G5. |
105 | | - |
106 | | -To learn more about the details and reasons for these recommendations read the [complete article](https://www.diabettech.com/artificial-pancreas/diy-looping-and-cgm/) published by Tim Street at [www.diabettech.com](https://www.diabettech.com). |
| 84 | +* xDrip always uses the transmitter's [native algorithm](https://navid200.github.io/xDrip/docs/Native-Algorithm.html) with current transmitters; there is no reason to disable it. |
| 85 | +* [Preemptive restarts](https://navid200.github.io/xDrip/docs/Preemptive-Restart.html) only function on old transmitters (firmware 1.6.5.25 or earlier), where they are needed to prevent the sensor stopping after 10 days. Recent (Firefly) transmitters ignore them. |
| 86 | +* Restarting a sensor on a Firefly transmitter requires [removing the transmitter](https://navid200.github.io/xDrip/docs/Remove-transmitter.html) and readings can be significantly in error after the restart, which is dangerous when looping: read [Restart a sensor](https://navid200.github.io/xDrip/docs/Restart-G6-sensor.html) in full and [calibrate carefully](https://navid200.github.io/xDrip/docs/Calibrate-after-G6Restart.html). |
107 | 87 |
|
108 | 88 | (xdrip-connect-g6-transmitter-for-the-first-time)= |
109 | 89 |
|
110 | | -### Connect G6 transmitter for the first time |
111 | | - |
112 | | -**For second and following transmitters see [Extend transmitter life](#xdrip-extend-transmitter-life) below.** |
113 | | - |
114 | | -Follow [these instructions](https://navid200.github.io/xDrip/docs/Starting-G6.html). |
115 | | - |
116 | | -(xdrip-transmitter-battery-status)= |
117 | | - |
118 | | -### Transmitter battery status |
119 | | - |
120 | | -* Battery status can be controlled in system status |
121 | | - → Hamburger Menu (1) → System Status (2) → If you are on the Classic Status Page (3) swipe the screen (4) to reach → G5/G6/G7 Status screen. |
122 | | - |
123 | | - |
124 | | - |
125 | | -* See [here](https://navid200.github.io/xDrip/docs/Battery-condition.html) for more information. |
| 90 | +#### Start, stop and replace sensors |
126 | 91 |
|
| 92 | +Follow the instructions: |
127 | 93 |
|
128 | | -(xdrip-extend-transmitter-life)= |
129 | | - |
130 | | -### Extend transmitter life |
131 | | - |
132 | | -* [Lifetime](https://navid200.github.io/xDrip/docs/Transmitter-lifetime.html) cannot be extended for Firefly transmitters: only rebatteried or modified transmitters. |
133 | | -* Follow [these instructions](https://navid200.github.io/xDrip/docs/Hard-Reset.html) for non-Firefly transmitters. |
| 94 | +* [Start a G6 or ONE transmitter](https://navid200.github.io/xDrip/docs/Starting-G6.html) |
| 95 | +* [Stop and start a G6 or ONE sensor](https://navid200.github.io/xDrip/docs/Dexcom/StartG6Sensor.html) |
| 96 | +* [Remove the transmitter from a sensor](https://navid200.github.io/xDrip/docs/Remove-transmitter.html) |
| 97 | +* [Transmitter lifetime](https://navid200.github.io/xDrip/docs/Transmitter-lifetime.html) can only be extended ([hard reset](https://navid200.github.io/xDrip/docs/Hard-Reset.html)) on rebatteried or modified transmitters, not on Firefly. |
134 | 98 |
|
135 | 99 | (xdrip-replace-transmitter)= |
136 | 100 |
|
137 | | -### Replace transmitter |
138 | | - |
139 | | -* Turn original Dexcom receiver off (if used). |
140 | | -* [Stop sensor](https://navid200.github.io/xDrip/docs/Dexcom/StartG6Sensor.html) (only if replacing sensor). |
141 | | - |
142 | | - |
143 | | -* Forget device in xDrip system status AND in smartphone’s BT settings (Will be shown as Dexcom?? whereas ?? are the last two digits of the transmitter serial no.) |
144 | | - → Hamburger Menu (1) → System Status (2) → If you are not on the Classic Status Page (3) swipe the screen (4) to reach it → then tap Forget Device (5). |
145 | | - |
146 | | - |
147 | | - |
148 | | - |
149 | | -* Remove transmitter (and sensor if replacing sensor). To remove transmitter without removing sensor see [this](https://navid200.github.io/xDrip/docs/Remove-transmitter.html), or this video [https://youtu.be/AAhBVsc6NZo](https://youtu.be/AAhBVsc6NZo). |
150 | | -* Put the old transmitter far away to prevent reconnection. A microwave is a perfect Faraday shield for this - but unplug power cord to be 100% sure no one is turning the microwave on. |
151 | | -* Follow [these instructions](https://navid200.github.io/xDrip/docs/Starting-G6.html). |
152 | | -* Do not turn original Dexcom receiver (if used) back on before xDrip shows first readings. |
153 | | - |
| 101 | +#### Replace a transmitter |
154 | 102 |
|
155 | | -### New Sensor |
| 103 | +* Turn the original Dexcom receiver off (if used) and do not turn it back on before xDrip shows readings. |
| 104 | +* Forget the device in xDrip (System Status → Forget Device) AND in the smartphone's Bluetooth settings (shown as Dexcom?? where ?? are the last two digits of the transmitter serial number). |
| 105 | +* Keep the old transmitter out of Bluetooth range to prevent reconnection. |
| 106 | +* Then follow [Start a G6 or ONE transmitter](https://navid200.github.io/xDrip/docs/Starting-G6.html). |
156 | 107 |
|
157 | | -* Turn original Dexcom receiver off (if used). |
158 | | -* Stop sensor following [these instructions](https://navid200.github.io/xDrip/docs/Dexcom/StartG6Sensor.html). |
| 108 | +### Dexcom G7, ONE+ and Stelo |
159 | 109 |
|
160 | | -* Insert and then start a new sensor following [these instructions](https://navid200.github.io/xDrip/docs/Starting-G6.html). |
161 | | - |
162 | | - |
163 | | -(xdrip-retrieve-sensor-code)= |
164 | | - |
165 | | -### Retrieve sensor code |
166 | | - |
167 | | -→ Hamburger Menu (1) → System Status (2) → If you are on the Classic Status Page (3) swipe the screen (4) to reach → G5/G6/G7 Status screen → Calibration Code. |
168 | | - |
169 | | - |
| 110 | +* Follow the [G7, ONE+ and Stelo instructions](https://navid200.github.io/xDrip/docs/Dexcom/G7.html) (a recent xDrip release is required — see the linked page). |
| 111 | +* See also the [Dexcom G7, ONE+ and Stelo page](../CompatibleCgms/DexcomG7.md) for the available setups with **AAPS**. |
170 | 112 |
|
171 | 113 | (xdrip-troubleshooting-dexcom-g5-g6-and-xdrip)= |
172 | 114 |
|
173 | | -### Troubleshooting Dexcom G5/G6 and xDrip |
174 | | - |
175 | | -#### Problem connecting transmitter |
176 | | - |
177 | | -Follow [these instructions](https://navid200.github.io/xDrip/docs/Connectivity-troubleshoot.html). |
178 | | - |
179 | | -#### Problem when starting new sensor |
| 115 | +### Troubleshooting Dexcom and xDrip |
180 | 116 |
|
181 | | -Follow [these instructions](https://navid200.github.io/xDrip/docs/Dexcom/SensorFailedStart.html). |
| 117 | +* [G6/ONE connectivity troubleshooting](https://navid200.github.io/xDrip/docs/Connectivity-troubleshoot.html) |
| 118 | +* [G7/ONE+/Stelo troubleshooting](https://navid200.github.io/xDrip/docs/Dexcom/G7_Troubleshooting.html) |
| 119 | +* [Problem when starting a new sensor](https://navid200.github.io/xDrip/docs/Dexcom/SensorFailedStart.html) |
| 120 | +* Full list: see **Troubleshooting** on the [xDrip Dexcom page](https://navid200.github.io/xDrip/docs/Dexcom_page.html). |
182 | 121 |
|
183 | 122 | ## Libre 1 |
184 | 123 |
|
|
0 commit comments